回路供电隔离器 IsoPAQ-612

产品型号IsoPAQ-612品牌瑞典INOR分类工业安全与信号调理模块 › 信号隔离器

输入回路供电隔离器 IsoPAQ-612 为 0(4)…20 mA 标准信号提供电气隔离,并以高精度将测量信号传送至输出端。

输出信号
0(4)-20 mA
输入信号
0(4)-20 mA
启动电流
< 200 mA
压降
Ca. 2.3 V at 20 mA

技术参数

技术规格
输入信号0(4)-20 mA
启动电流< 200 mA
压降Ca. 2.3 V at 20 mA
过载≤ 50 mA, 30 V
输出信号0(4)-20 mA
负载600 Ω
响应时间 T995 ms
残余纹波< 10 mV rms
传输误差< 0.1 % full scale
负载误差< 0.05 % of measured value / 100 Ω load
温度系数< 100 ppm/K
测试电压3 kV AC, 50 Hz, 1 min. all circuits against one a否ther
工作电压(基本绝缘)600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1
防触电保护Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits.
环境温度Operation – 25 to + 70 °C (– 13 to + 158 °F) Transport and Storage – 40 to + 85 °C (– 40 to + 185 °F)
电磁兼容EN 61326-1
结构形式62 x 96,5 x 107 mm , protection class IP 20, mounting on 35 mm DIN 导轨 acc. to EN 60715
重量Approx. 70 g

选型建议与注意事项

IsoPAQ-612 回路供电隔离器 为 瑞典INOR 产品,归入 工业安全与信号调理模块 / 信号隔离器。

  • 本安回路中,安全栅的 Uo、Io、Po 必须分别低于现场仪表的 Ui、Ii、Pi;电缆的分布电容 Cc 与电感 Lc 要计入回路总参数,不能只核算仪表本体。
  • 齐纳式安全栅必须接入等电位接地系统,接地连接单独引至接地干线;隔离式安全栅依靠电气隔离,一般不需要专门接地。
  • 非本安侧接入控制系统时,要核算回路总负载(安全栅内阻 + 线路电阻 + 控制器输入阻抗),确保变送器在其负载能力范围内。
  • 本安与非本安端子不可接反,接线前须核对端子标识;两类线缆应分开走线并保持间距。

产品特性

  • 输入回路供电隔离器 IsoPAQ-612 为 0(4)…20 mA 标准信号提供电气隔离,并以高精度将测量信号传送至输出端。
  • 该装置可避免干扰电压窜入,并有效抑制寄生噪声。2.3 V 的极低压降与高精度使其在系统设计中成为 IsoPAQ-612 的首选理由。
  • 智能化设计并避免使用高度集成元件,带来极长的使用寿命与可靠性,且不会使测量信号失真。

接线与安装要点

  • 输入回路供电隔离器 IsoPAQ-612 为 0(4)…20 mA 标准信号提供电气隔离,并以高精度将测量信号传送至输出端。

接线前请确认回路已断电,并按端子标识区分本安侧与非本安侧。详细接线图见产品样本。

相关资料

  • IsoPAQ-612 产品样本(Catalog Sheet)_英文版PDF
  • IsoPAQ-612 产品样本(Catalog Sheet)_德语PDF

典型应用

过程回路信号隔离
危险区域信号调理

询价与选型咨询

填写需求后我们会在一个工作日内回复,技术问题也可直接致电 021-66020232。

相关产品推荐

按分类、技术参数与关键词自动匹配